Product selection from HOMELINE

HomeLine 15A/1P CHOM AFI Circuit Breaker

Article #02655086 Item #000347075 Model #CHOM115AFI Format 15Ax120Vx1P
76 . 99 Each
This item is not currently available for immediate purchase, but can be ordered by visiting the selected store.
Delivery +
Will ship next business day
Most orders will ship next business day. Some orders may take up to 7-14 days (where inventory is not available in store). Delivery time may vary due to factors beyond our control. You will receive an email when your order has shipped. See all details.
Gift cards are delivered 2 to 5 days following the confirmation of your order in major urban areas and within 7 business days for remote locations. Gift Cards can be delivered across Canada, except the Yukon, Nunavut, Northwest Territories and Northern Quebec. See all details.
Sold online only. Total price includes delivery without any additional fees. Delivery time may vary due to factors beyond the control of RONA. Some restrictions may apply for remote areas. Signature may be required. Deliveries are made to threshold or curbside only, subject to carrier discretion.
The earliest delivery date displayed is only an estimate. The actual delivery date may change based on availability of products, or due to other circumstances beyond our control. Appliance delivery date can be selected in the checkout. If there is no option to schedule your appliance delivery, our team will contact you to schedule a delivery within 24 hours. Learn More.
RONA's third-party partners handle all express deliveries. Only available for select in-store items in sufficient stock at the participating selected store. Delivery address must be within delivery zone of the selected participating store. Weight limit of 1,475 Kg (3,250 lbs) per order. Not available on national/provincial holidays. Service may not be available due notably high in-store traffic, bad weather conditions or any other situation affecting the availability of the service. See all details.
Our expert center will contact you to schedule a delivery within 24 hours. The delay for delivery is an estimate and may vary according to the availability of products, or due to other circumstances beyond our control. Delivery prices only include curbside delivery, except for appliances. Delivery service is only available within a 50 km radius from the selected store (75 km for RONA+ stores). Additional charges may apply for installation. We will not leave deliveries at an unattended site – note that additional delivery charges may apply for subsequent delivery attempts. See all details.
Hassle-Free Returns 90 days to return or exchange in original condition and packaging. Read Return Policy
icon-wishlist

Description

As of January 2002, the Canadian Electrical code requires the use of Arc Fault Circuit Interrupters (AFCIs) in all branch circuits that supply outlets in bedrooms for new residential construction. In addition to your bedrooms, consider using arc fault circuit interrupters for other living areas of the home to increase your protection and added peace of mind. A few of the typical conditions where arc faults may start include: damaged wires, worn electrical insulation, loose electrical connections, overheated or stressed electrical cords. Detects unintended arc faults, overloads and short circuits. Familiar installation procedure - Installation is similar to that of a ground-fault circuit interrupter. Green push to test button. CSA approved to only install in Canadian HomeLine Loadcentres
  • As of January 2002, the Canadian Electrical code requires the use of Arc Fault Circuit Interrupters (AFCIs) in all branch circuits that supply outlets in bedrooms for new residential construction
  • A few of the typical conditions where arc faults may start include: damaged wires, worn electrical insulation, loose electrical connections, overheated or stressed electrical cords
  • Detects unintended arc faults, overloads and short circuits
  • Familiar installation procedure - Installation is similar to that of a ground-fault circuit interrupter
  • Green push to test button
  • Accepts Al/Cu conductors
  • Lug Range #14-#8
  • CSA approved to only install in Canadian Homeline Loadcentres
  • Compatible with GFCI receptacles

Product specifications

Width Measurement
1-in
UL Safety Listing
No
Amps(Amps)
15
Circuit Breaker Size
1 inch
Circuit Breaker Type
Combination arc fault
Circuit Breaker Voltage
120
CSA Safety Listing
Yes
ETL Safety Listing
No
Interrupting Amp Listing(Amps)
10000
Number of Poles
1
Phase
Single phase (120/240)
Plug-On Neutral
No
Power Capacity
15-amp
Series
CHOM
Series Name
CHOM
Type
Combination arc fault